Skip to content Skip to navigation menu

Pre-Filters, Filters & Adaptors

132 Results found

Display using
  • Category

  • Brand

  • EN 143 (Filter Class)

  • Environmental Claim

  • Price Range

  • Code:115100
    Discover…
    Part of the 6000 Series of filters, these 3M 6099 ABEK2P3 R combination gas filters are for use with a wide range of 3M full-face masks and are easy to click into place thanks to the bayonet connection. They offer respiratory protection against organic and inorganic vapours, acid gases, ammonia and particulates.

    Learn more…
    • Protects against organic vapours (with a boiling point above 65°C), inorganic vapours, acid gases, ammonia and its derivatives, and particulates
    • For use with 3M full-face respirator masks only
    • Bayonet connection with a simple twist-and-click fitting
    • Swept-back position maintains a good field of vision
    • Maximum use concentration: 20 x workplace exposure limit (WEL) or 5000ppm whichever is lower for certain organic and inorganic vapours, acid gases and ammonia and its derivatives; up to 40 x WEL for particulates

    Get technical…
    EN 14387:2004 + A1:2008 ABEK2P3 R
  • Code:114700
    Discover…
    Part of the 6000 Series of filters, these 3M 6059 ABEK1 combination gas filters are for use with a wide range of 3M full-face and half-face masks, and are easy to click into place thanks to the bayonet connection. They offer respiratory protection against organic vapours, inorganic vapours, acid gases and ammonia.

    Learn more…
    • Protects against organic vapours, inorganic vapours, acid gases, ammonia and its derivatives
    • Ideal for working with weedkillers, pesticides, cleaning chemicals or solvent-based paints
    • For use with 3M half-face and full-face respirator masks
    • Bayonet connection with a simple twist-and-click fitting
    • Lightweight with low breathing resistance
    • Swept-back position maintains a good field of vision
    • Maximum use concentration for full-face masks: 20 x workplace exposure limit (WEL) or 1000ppm
    • Maximum use concentration for half-face masks: 10 x workplace exposure limit (WEL) or 1000ppm

    Get technical…
    EN 14387:2004 + A1:2008 ABEK1
  • Code:119400
    Discover…
    Part of the 5000 Series of filters, these 3M 5911 P1 R particulate filters are for use with a wide range of 3M full-face and half-face masks. They offer low-level respiratory protection against fine dusts, and oil- and water-based mists, and they’re easy to click into place thanks to the bayonet connection.

    Learn more…
    • Protects against low levels of airborne particles including fine dust, and water- and oil-based mists
    • For use with 3M half-face and full-face respirator masks
    • Must be combined with a 3M 501 retainer and either a 3M 6000 Series gas and vapour filter or a 3M 603 filter platform (available separately)
    • Bayonet connection with a simple twist-and-click fitting
    • Lightweight with low breathing resistance
    • Maximum use concentration: 4 x workplace exposure limit (WEL)

    Get technical…
    EN 143 P1 R
  • Code:119600
    Discover…
    The 3M 501 filter retainers allow the user to add a 3M 5000 Series particulate filter to a 6000 Series gas and vapour filter for combined respiratory protection.

    Learn more…
    • For use with 3M full-face and half-face respirator masks
    • Allows a 3M 5000 Series particulate filter to be combined with a 3M 6000 Series gas and vapour filter for protection against airborne particles
    • Easy to fit into position
  • Code:119900
    Discover…
    Part of the 5000 Series of filters, these 3M 5935 P3 R particulate filters are for use with a wide range of 3M full-face and half-face masks. They offer respiratory protection against fine dusts, and oil- and water-based mists, and they’re easy to click into place thanks to the bayonet connection.

    Learn more…
    • Protects against airborne particles including fine dust, and water- and oil-based mists
    • For use with 3M half-face and full-face respirator masks
    • Must be combined with a 3M 501 retainer and either a 3M 6000 Series gas and vapour filter or a 3M 603 filter platform (available separately)
    • Bayonet connection with a simple twist-and-click fitting
    • Lightweight with low breathing resistance
    • Maximum use concentration: 20 x workplace exposure limit (WEL)
    • Must always be used in pairs

    Get technical…
    EN 143 P3 R
  • Code:119800
    Discover…
    Part of the 5000 Series of filters, these 3M 5925 P2 R particulate filters are for use with a wide range of 3M full-face and half-face masks. They offer respiratory protection against fine dusts, and oil- and water-based mists, and they’re easy to click into place thanks to the bayonet connection.

    Learn more…
    • Protects against airborne particles including fine dust, and water- and oil-based mists
    • For use with 3M half-face and full-face respirator masks
    • Must be combined with a 3M 501 retainer and either a 3M 6000 Series gas and vapour filter or a 3M 603 filter platform (available separately)
    • Bayonet connection with a simple twist-and-click fitting
    • Lightweight with low breathing resistance
    • Maximum use concentration: 10 x workplace exposure limit (WEL)

    Get technical…
    EN 143 P2 R
  • Code:123500
    Discover…
    Part of the 6000 Series of filters, these 3M 6096 AE1HgP3 R combination gas filters are for use with a wide range of 3M full-face and half-face masks and are easy to click into place thanks to the bayonet connection. They offer respiratory protection against organic vapours, acid gases, mercury and particulates.

    Learn more…
    • Protects against organic vapours (with a boiling point above 65°C), acid gases, mercury and particulates
    • For use with 3M full-face and half-face respirator masks
    • Bayonet connection with a simple twist-and-click fitting
    • Swept-back position maintains a good field of vision
    • Maximum use concentration for full-face masks: 20 x workplace exposure limit (WEL) or 1000ppm whichever is lower for mercury; up to 40 x WEL for particulates
    • Maximum use concentration for half-face masks: 10 x workplace exposure limit (WEL) or 1000ppm whichever is lower for mercury; up to 20 x WEL for particulates

    Get technical…
    EN 14387:2004 + A1:2008 AE1HgP3 R
  • Code:126500
    Discover…
    For use with the 3M Secure Click HF-800 Series of reusable half-face masks, these particulate filters are simple to fit into place and are secured with an audible click so you can be sure they’re fitted correctly.

    Learn more…
    • Filter cartridges for use with the 3M Secure Click HF-800 and HF-800SD reusable half-face masks
    • Dual-flow construction allows for easier breathing
    • Protect against particulates
    • Easy to fit into place; simply align the connectors and push until you hear a click
    • Weight: 14g
    • Filter retainer sold separately
  • Code:126900
    Discover…
    For use with the 3M Secure Click HF-800 Series of reusable half-face masks, these organic vapour filters are simple to fit into place and are secured with an audible click so you can be sure they’re fitted correctly.

    Learn more…
    • Filter cartridges for use with the 3M Secure Click HF-800 and HF-800SD reusable half-face masks
    • Dual-flow construction allows for easier breathing
    • Protect against certain organic vapours with a boiling point above 65°C
    • Easy to fit into place; simply align the connectors and push until you hear a click
    • Weight: 90g
    • Filter retainer sold separately
  • Code:126800
    Discover…
    For use with the 3M Secure Click HF-800 Series of reusable half-face masks, these particulate filters are simple to fit into place and are secured with an audible click so you can be sure they’re fitted correctly.

    Learn more…
    • Filter cartridges for use with the 3M Secure Click HF-800 and HF-800SD reusable half-face masks
    • Dual-flow construction allows for easier breathing
    • Protect against particulates
    • Easy to fit into place; simply align the connectors and push until you hear a click
    • Weight: 2g
    • Supplied as a pack of four as two filters are used on each side and should be used with the D8000 Series of gas filters and filter retainers (sold separately)
  • Code:127000
    Discover…
    For use with the 3M Secure Click HF-800 Series of reusable half-face masks, these organic vapour filters are simple to fit into place and are secured with an audible click so you can be sure they’re fitted correctly.

    Learn more…
    • Filter cartridges for use with the 3M Secure Click HF-800 and HF-800SD reusable half-face masks
    • Dual-flow construction allows for easier breathing
    • Protect against certain organic vapours with a boiling point above 65°C
    • Easy to fit into place; simply align the connectors and push until you hear a click
    • Weight: 91g
    • Filter retainer sold separately
  • Code:127100
    Discover…
    For use with the 3M Secure Click HF-800 Series of reusable half-face masks, these ammonia and organic vapour filters are simple to fit into place and are secured with an audible click so you can be sure they’re fitted correctly.

    Learn more…
    • Filter cartridges for use with the 3M Secure Click HF-800 and HF-800SD reusable half-face masks
    • Dual-flow construction allows for easier breathing
    • Protect against ammonia and derivatives, and certain organic vapours with a boiling point above 65°C
    • Easy to fit into place; simply align the connectors and push until you hear a click
    • Weight: 106g
    • Filter retainer sold separately